Insulation Calculator

Enter the area, your climate zone and what you are insulating. You get the R-value ENERGY STAR recommends and the bags of blown-in insulation, or the batts or rolls for your stud or joist spacing, needed to reach it.

Attic or floor: length times width. Wall: length times height.

Find your county on the ENERGY STAR zone map linked in the sources.

What are you insulating?

Leave on the recommendation, or pick the R-value on your plans.

Insulation type

Leave at 0 to use the Owens Corning AttiCat chart. For another product, type the figure from its chart at your R-value.

0 by default. Add some for cuts and odd-shaped bays.

Printed on the saved estimate.

Insulation estimate

Your insulation estimate

Insulation to order

28 bags

For R-49 over 1,100 sq ft.

ENERGY STAR recommends

R-49

Minimum depth

17 in

How the order is worked out
StepFigure
ENERGY STAR recommendationZone 4C, 5 or 6, an attic with 3 to 4 inches already in placeR-49
R-value to addTaken from the recommendationR-49
Area to coverNo extra added1,100 sq ft
Installed depthMinimum thickness for R-49 on the AttiCat chart17 in
Blown-in insulation25 bags per 1,000 sq ft for R-49 (AttiCat chart)28 bags
How we calculated this

Recommended R-value.Taken from ENERGY STAR's table for adding insulation to an existing wood-framed home, which is based on the 2021 International Energy Conservation Code. For a topped-up attic the figure is the R-value to add on top of the 3 to 4 inches already there.

ENERGY STAR recommended R-values by climate zone
ZoneBare atticAttic top-upFloor
1R-30R-25R-13
2R-49R-38R-13
3R-49R-38R-19
4A or 4BR-60R-49R-19
4C, 5 or 6R-60R-49R-30
7 or 8R-60R-49R-38

Blown-in.Bags are the area times the bags per 1,000 sq ft on Owens Corning's AttiCat coverage chart for the R-value, rounded up. Where the chart has no row for the R-value, the next row up is used. Treat the chart as a minimum and install both the bag count and the depth it lists. If you are blowing another product, type the coverage per bag from its own chart.

Batts and rolls. One piece fills one bay between studs or joists, so it accounts for the full on-center spacing times its length. The area is divided by that and rounded up. Framing is counted as if it were insulated, which leaves a small built-in margin.

Extra. Nothing is added unless you enter a percentage. Add some for odd-shaped bays, cuts around wiring and pipes, or a low attic that is hard to fill evenly.

What this is not. It is not an energy audit and it does not replace your local code. Air sealing, ventilation baffles and vapor retarders are not counted.

Sources, all opened on November 20, 2026:

Save your result

Example: topping up a 1,100 sq ft attic in climate zone 5

For an attic in climate zone 5 that already has 3 to 4 inches of insulation, ENERGY STAR recommends adding R-49. Over 1,100 sq ft that takes 28 bags of blown-in insulation at 25 bags per 1,000 sq ft, blown to at least 17inches deep, on Owens Corning's AttiCat chart. With batts instead, it is 207 batts 48 inches long between joists 16 inches on center.

Example insulation estimate

Insulation to order

28 bags

For R-49 over 1,100 sq ft.

ENERGY STAR recommends

R-49

Minimum depth

17 in

How the order is worked out
StepFigure
ENERGY STAR recommendationZone 4C, 5 or 6, an attic with 3 to 4 inches already in placeR-49
R-value to addTaken from the recommendationR-49
Area to coverNo extra added1,100 sq ft
Installed depthMinimum thickness for R-49 on the AttiCat chart17 in
Blown-in insulation25 bags per 1,000 sq ft for R-49 (AttiCat chart)28 bags
How we calculated this

Recommended R-value.Taken from ENERGY STAR's table for adding insulation to an existing wood-framed home, which is based on the 2021 International Energy Conservation Code. For a topped-up attic the figure is the R-value to add on top of the 3 to 4 inches already there.

ENERGY STAR recommended R-values by climate zone
ZoneBare atticAttic top-upFloor
1R-30R-25R-13
2R-49R-38R-13
3R-49R-38R-19
4A or 4BR-60R-49R-19
4C, 5 or 6R-60R-49R-30
7 or 8R-60R-49R-38

Blown-in.Bags are the area times the bags per 1,000 sq ft on Owens Corning's AttiCat coverage chart for the R-value, rounded up. Where the chart has no row for the R-value, the next row up is used. Treat the chart as a minimum and install both the bag count and the depth it lists. If you are blowing another product, type the coverage per bag from its own chart.

Batts and rolls. One piece fills one bay between studs or joists, so it accounts for the full on-center spacing times its length. The area is divided by that and rounded up. Framing is counted as if it were insulated, which leaves a small built-in margin.

Extra. Nothing is added unless you enter a percentage. Add some for odd-shaped bays, cuts around wiring and pipes, or a low attic that is hard to fill evenly.

What this is not. It is not an energy audit and it does not replace your local code. Air sealing, ventilation baffles and vapor retarders are not counted.

Sources, all opened on November 20, 2026:

How to calculate insulation

The amount of insulation you need is the area times a coverage rate, and the coverage rate depends on the R-value you want. So the first step is the target R-value, and the second is the product.

  1. Find the R-value. Use the ENERGY STAR recommendation for your climate zone, or the figure on your plans.
  2. Measure the area. Attic and floor: length x width. Wall: length x height.
  3. Blown-in: bags = area x bags per 1,000 sq ft / 1,000, rounded up.
  4. Batts or rolls: pieces = area / (spacing x piece length), rounded up.

Recommended R-values by climate zone

These are ENERGY STAR's figures for adding insulation to an existing wood-framed home.

  • Zone 1: R-30 in an uninsulated attic, add R-25 to an attic with 3 to 4 inches, R-13 in a floor.
  • Zone 2: R-49, add R-38, floor R-13.
  • Zone 3: R-49, add R-38, floor R-19.
  • Zones 4A and 4B: R-60, add R-49, floor R-19.
  • Zones 4C, 5 and 6: R-60, add R-49, floor R-30.
  • Zones 7 and 8: R-60, add R-49, floor R-38.

The map on ENERGY STAR's page shows the zone for every county. Your local building code can ask for more or less, and it wins.

A worked example: blown-in

Take a 1,100 sq ft attic in climate zone 5 with 3 to 4 inches of old insulation.

  • ENERGY STAR recommends adding R-49.
  • Owens Corning's AttiCat chart lists 25 bags per 1,000 sq ft for R-49.
  • Bags: 1,100 x 25 / 1,000 = 27.5, so 28 bags.
  • The chart's minimum depth for R-49 is 17 inches.

The example result above is produced by the same calculation, so the numbers always agree.

A worked example: batts

The same 1,100 sq ft attic, with batts laid between joists 16 inches on center.

  • One 48 inch batt accounts for 16 x 48 = 768 square inches, which is 5.33 sq ft.
  • Pieces: 1,100 / 5.33 = 206.3, so 207 batts.

A batt is about an inch narrower than the spacing because the joist takes up the rest. Counting the full spacing is what makes the area and the piece count agree. Type the pieces per package from the label and the calculator turns the count into packages.

Batts, rolls or blown-in

Blown-in insulation suits an open attic: it fills around wiring and odd framing, and depth is easy to check with a ruler. Batts and rolls suit open stud walls and floors, where each piece fits one bay. Owens Corning lists batts 48, 93, 96 and 105 inches long and rolls of 25 ft, 32 ft and just over 39 ft, in widths for framing 16 or 24 inches on center. For a framed cavity, its guidance is that the batt thickness should match the depth of the framing.

What changes the count

  • Existing insulation. In an attic you only need the difference, which is why the table has a top-up column.
  • The product. Coverage per bag differs between brands and between fiberglass and cellulose. If you are not using AttiCat, type the coverage from your bag's chart.
  • Recessed lights. Owens Corning says to keep insulation 3 inches away from a recessed light unless the fixture is rated for insulation contact, which reduces the area slightly.
  • Waste. Nothing is added by default. Add a few percent for cut batts and awkward bays.

Pricing the job

Type your supplier's price per bag or per package and the result adds a material cost. No price is built in, because insulation prices change by store and by season.

If insulation is your trade, the takeoff is the quick part and getting the call is the slow part. Lever builds websites for contractors that bring in estimate requests from your service area.

Common Questions

How much insulation do I need?

Two numbers decide it: the area in square feet and the R-value you are aiming for. For blown-in insulation, multiply the area by the bags per 1,000 sq ft on the product's coverage chart for that R-value. For batts, divide the area by what one batt covers, which is the stud or joist spacing times the batt length. The calculator does both and rounds up to whole bags or pieces.

What R-value do I need in my attic?

ENERGY STAR recommends R-30 for an uninsulated attic in climate zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 through 8. If the attic already has 3 to 4 inches of insulation, it recommends adding R-25 in zone 1, R-38 in zones 2 and 3, and R-49 in zones 4 through 8. The figures are based on the 2021 International Energy Conservation Code.

How many bags of blown-in insulation do I need for 1,000 sq ft?

On Owens Corning's AttiCat coverage chart, 1,000 sq ft of attic takes 15 bags for R-30, 19 bags for R-38, 25 bags for R-49 and 32 bags for R-60, rounded up to whole bags. Other products cover differently, so use the chart printed on the bag you buy.

How deep should blown-in attic insulation be?

It depends on the product and the R-value. Owens Corning's AttiCat chart lists a minimum depth of 10.75 inches for R-30, 13.5 inches for R-38, 17 inches for R-49 and 20.5 inches for R-60. Cellulose and other loose-fill products reach the same R-value at different depths.

How many batts of insulation do I need for a wall?

One batt fills one stud bay. A wall 20 ft long and 8 ft high is 160 sq ft, and a 93 inch batt in framing 16 inches on center accounts for 10.33 sq ft of it, so the wall takes 16 batts. Windows and doors reduce the count a little, and the offcuts usually fill the short bays above and below them.

What R-value do I need for a floor or crawl space?

For a floor, ENERGY STAR recommends R-13 in climate zones 1 and 2, R-19 in zones 3, 4A and 4B, R-30 in zones 4C, 5 and 6, and R-38 in zones 7 and 8.

What R-value should wall insulation be?

ENERGY STAR does not give one cavity figure for existing walls. Its advice, when the siding is off, is to blow insulation into an empty cavity and add insulating sheathing under the new siding: R-5 in zone 3 and R-5 to R-10 in zones 4 through 8. For open framing, Owens Corning's guidance is that the batt thickness should match the depth of the studs, so check the thickness on the package against your wall.

Two ways to get started

Local Business Website, Monthly

Your new website, built and looked after for you

We build your local business website, then handle the hosting, the support and every change for $249 a month. Cancel anytime and the site goes with you. If the site does not bring you one new customer inquiry in its first 60 days, you get every dollar back and keep the site.

  • A page for each service you offer, written for your business and your service area
  • An intake form that sends every inquiry to your inbox within seconds
  • We move your domain and bring over your content and photos
  • Your Google listing updated to show the right hours and number and point to the new site
  • Hosting, support and up to 3 hours of work a month
$249a month

Turnaround: Live within five business days of your changes and your domain login.

You pay on Stripe's secure checkout page. We never see your card number.

Local Business Website, One Time

Pay once and the site is yours

We build your local business website for $1,999 and it is yours from the day it goes live, with the first year of hosting and support included. After year one, $59 a month keeps it online, keeps your form sending inquiries and covers small changes. That $59 is not charged today. If the site does not bring you one new customer inquiry in its first 60 days, you get every dollar back and keep the site.

  • A page for each service you offer, written for your business and your service area
  • An intake form that sends every inquiry to your inbox within seconds
  • We move your domain and bring over your content and photos
  • Your Google listing updated to show the right hours and number and point to the new site
  • The first year of hosting and support included
$1,999one time

Turnaround: Live within five business days of your changes and your domain login.

You pay on Stripe's secure checkout page. We never see your card number.